scada-ics-security

Fail

Audited by Socket on Sep 19, 2026

4 alerts found:

Securityx2MalwareAnomaly
SecurityMEDIUM
SKILL.md

SUSPICIOUS. The skill’s capabilities align with its stated purpose, but that purpose is to enable an AI agent to perform offensive ICS security testing, including fuzzing, manipulation, and disruption of safety-critical systems. Even with safety disclaimers, this materially increases real-world operational risk. Install provenance is only partially clear from the evidence, and some named tools appear ambiguous or legacy. There is no obvious credential theft or covert exfiltration, so this is not confirmed malware, but it is a high-risk offensive security skill.

Confidence: 92%Severity: 86%
MalwareHIGH
payloads.md

This fragment is an active ICS/SCADA reconnaissance and attack toolkit. It contains code capable of enumerating PLCs and industrial devices, extracting memory and programs, brute-forcing HMI credentials, injecting control commands, disabling communications, rebooting outstations, forging protection messages, writing PLC memory, and modifying Modbus RTU devices. Although it does not show covert persistence or data exfiltration, the explicit control and disruption functionality presents a severe operational and safety risk. It should not be executed against production systems and should be isolated or removed unless its use is strictly authorized in a controlled laboratory.

Confidence: 98%Severity: 98%
AnomalyLOW
guides/purdue-model-attack-paths-guide.md

This is security-training documentation describing authorized Purdue Model segmentation testing and an IT-to-OT attack-chain simulation. It contains no executable malware or direct data theft mechanism in the displayed fragment. The commands are dual-use and could cause operational impact or unauthorized access if run against real networks, and the plaintext credential is a security weakness. Review and execute only in an isolated, explicitly authorized lab; replace example credentials and avoid embedding real secrets.

Confidence: 94%Severity: 58%
SecurityMEDIUM
guides/modbus-s7comm-attack.md

The fragment is not conventional malware or an automatically executing supply-chain payload; it is offensive ICS/PLC attack documentation with executable examples. It contains high-impact commands for reading and modifying PLC memory, stopping PLCs, brute-forcing passwords, intercepting traffic, spoofing responses, fuzzing protocols, and evading monitoring. The lab-use warnings reduce ambiguity about intent but do not remove the operational danger. Treat the content as dual-use security testing material and restrict distribution or execution to authorized isolated environments.

Confidence: 98%Severity: 78%
Audit Metadata
Analyzed At
Sep 19, 2026, 04:40 PM
Package URL
pkg:socket/skills-sh/brucesongs%2Fkali-claw%2Fscada-ics-security%2F@510a77531fc5bde73f62efaf4d3da2feec87226e4dfe13b76cc87f74e4cc326a